Magnetic Latching Relay characteristics

17-10-2022

 Magnetic Latching Relay    characteristics:


2A Contact switching capability


Relays for electric meters


Voltage between contacts up to 2.5kV


The voltage between the coil and the contact is 4kV


The contact gap is more than 1.2mm


Magnetic holding relay characteristics

Matters needing attention


1. The factory state of the magnetic retaining relay is in the state of action or return, but it may change due to the impact of transportation or relay installation and other factors, so please set it to the state of return or action as required when using it (when the power is connected);


2. In order to ensure the action or return of the Magnetic Latching Relay, the excitation voltage applied to the coil shall reach the rated voltage, and the pulse width shall be greater than 5 times of the action or return time; Do not apply voltage to both the action coil and the return coil; Do not apply voltage to the coil for a long time (more than 1 minute);


3. Select the relay with PCB lead out, recommend the welding temperature and time: 240℃~260°C, 2s~5s; Please do not use reflow welding, if you really have requirements, please contact our technical staff; Generally, the welding temperature of wave welding should not exceed 2s at 250℃.


Get the latest price? We'll respond as soon as possible(within 12 hours)

Privacy policy