Latching Relay
-
Hot
R618-120-12-S280-01 100A Magnetic Latching Relay with shunt
R618-120-12-S280-01 100A Single Relay,Relay is an automatic switching component with isolation function, widely used in remote control, telemetry, communication, automatic control, mechatronics and power electronic equipment, is one of the most important control components.
Email Details
Contact Form: 1B Operate (Default Form)
Contact Material: AgSnO2
Contact Resistance: ≤2 mΩ(1A/6VDC)
Switching Current: 100A;
Switching Voltage: 250VAC max
Switching power: 22500VA max
Dielectric Strength: 4kV/1min (between coil and contacts)
RoHS Compliance -
Hot
SH615-80-12-C102-01 Magnetic Latching Relay with CT
SH615-80-12-C102-01 80A Single Relay,Relay is an automatic switching component with isolation function, widely used in remote control, telemetry, communication, automatic control, mechatronics and power electronic equipment, is one of the most important control components.
Email Details
Contact Form: 1B Operate (Default Form)
Contact Material: AgSnO2
Contact Resistance: ≤2 mΩ(1A/6VDC)
Switching Current: 80A;
Switching Voltage: 250VAC max
Switching power: 20000VA max
Dielectric Strength: 4kV/1min (between coil and contacts)
RoHS Compliance -
Hot
SH617-90-12DT2 90A Magnetic Latching Relay
SH617-90-12DT2 90A Single Relay,Relay is an automatic switching component with isolation function, widely used in remote control, telemetry, communication, automatic control, mechatronics and power electronic equipment, is one of the most important control components.
Email Details
Contact Form: 1B Operate (Default Form)
Contact Material: AgSnO2
Contact Resistance: ≤2 mΩ(1A/6VDC)
Switching Current: 90A;
Switching Voltage: 250VAC max
Switching power: 22500VA max
Dielectric Strength: 4kV/1min (between coil and contacts)
RoHS Compliance -
SH619-120-12DT2 120A Magnetic Latching Relay
SH619-120-12DT2 120A Relay,Relay is an automatic switching component with isolation function, widely used in remote control, telemetry, communication, automatic control, mechatronics and power electronic equipment, is one of the most important control components.
Email Details
Contact Form:1B Operate
Contact Material: AgSnO2
Contact Resistance: ≤2 mΩ(1A/6VDC)
Switching Current: 100&120A;
Switching Voltage: 250VAC max
Switching power: 30000VAmax
Dielectric Strength: 4kV/1min (between coil and contacts)
RoHS Compliance, UC3 Approval
Dimensions (mm): 52.5×43.2×21.5 -
Hot
SH618-120-12DT2 120A Magnetic Latching Relay
SH618-120-12DT2 120A Single Relay,Relay is an automatic switching component with isolation function, widely used in remote control, telemetry, communication, automatic control, mechatronics and power electronic equipment, is one of the most important control components.
Email Details
Contact Form:1B Operate
Contact Material: AgSnO2
Contact Resistance: ≤2 mΩ(1A/6VDC)
Switching Current: 120A;
Switching Voltage: 250VAC max
Switching power: 30000VA max
Dielectric Strength: 4kV/1min (between coil and contacts)
RoHS Compliance -
Hot
SH617-100-12DT2 100A Magnetic Latching Relay
SH617-100-12DT2 100A Single Relay,Relay is an automatic switching component with isolation function, widely used in remote control, telemetry, communication, automatic control, mechatronics and power electronic equipment, is one of the most important control components.
Email Details
Contact Form:1B Operate
Contact Material: AgSnO2
Contact Resistance: ≤2 mΩ(1A/6VDC)
Switching Current: 100A;
Switching Voltage: 250VAC max
Switching power: 25000VA max
Dielectric Strength: 4kV/1min (between coil and contacts)
RoHS Compliance -
SH615-60-12DT2 60A Magnetic Latching Relay
SH615-60-12DT2 60A Latching Relay,Relay is an automatic switching component with isolation function, widely used in remote control, telemetry, communication, automatic control, mechatronics and power electronic equipment, is one of the most important control components.
Email Details
Contact Form:1B Operate
Contact Material: AgSnO2
Contact Resistance: ≤2 mΩ(1A/6VDC)
Switching Current: 60A;
Switching Voltage: 250VAC max
Switching power: 20000VA max
Dielectric Strength: 4kV/1min (between coil and contacts)
RoHS Compliance -
SH639-120-12DT2 120A Three Phase Magnetic Latching Relay
SH639-120-12DT2 for three phase Wh meter,Relay is an automatic switching component with isolation function, widely used in remote control, telemetry, communication, automatic control, mechatronics and power electronic equipment, is one of the most important control components.
Email Details
Contact Form:3B Operate
Contact Material: AgSnO2
Contact Resistance: ≤2 mΩ(1A/6VDC)
Switching Current: 3X120A;
Switching Voltage: 250VAC max
Switching power: 30000VA max
Dielectric Strength: 4kV/1min (between coil and contacts)
RoHS Compliance, -
SH638-100-12DT2 100A Three Phase Magnetic Latching Relay
SH638-100-12DT2 for three phase Wh meter,Relay is an automatic switching component with isolation function, widely used in remote control, telemetry, communication, automatic control, mechatronics and power electronic equipment, is one of the most important control components.
Email Details
Contact Form: 3B Operate Contact Material: AgSnO2
Contact Resistance: ≤2 mΩ(1A/6VDC)
Switching Current: 3x100A;
Switching Voltage: 250VAC max
Switching power: 25000VA max
Dielectric Strength: 4kV/1min (between coil and contacts)
RoHS Compliance,