Shunt Resistor
-
Fixed Value Shunt SEFL-150A-60mV-01
Fixed fixed value shunt is a kind of external shunt which can directly act on the analog display instrument when the measured DC current is less than 10kA and is used to expand the DC current measurement range, or it can be regarded as a standard resistor for current sampling in the sequential circuit, and its sampling voltage can be regarded as the analog signal of the primary current for measurement.
Email Details -
Fixed Value Shunt SEFL-100A-100mV-01
Fixed fixed value shunt is a kind of external shunt which can directly act on the analog display instrument when the measured DC current is less than 10kA and is used to expand the DC current measurement range, or it can be regarded as a standard resistor for current sampling in the sequential circuit, and its sampling voltage can be regarded as the analog signal of the primary current for measurement.
Email Details -
Current Shunt Resistor EBSA10300-32-11-21-4.2-V1
Material: Copper-Manganin-Copper
Operating Temperature Range: -40℃~+80℃
Shunt is one of the main current sensor used in kWh meter, especially in single phase kWh meter. It's much more economical than current transformer, so three-phase meters is more and more adopting shunt solution with regard to lower cost. Electron Beam Welding shunt (E-B Shunt) is high technology product, and has strict requirement for manganin and copper 99.9% materials, so the quality and appearance is excellent after vacuum welding.Electron-Beam Shunt Low Temperature Drift Shunt Copper-Manganese-Copper Shunt Current Shunt ResistorEmail Details -
150 uΩ Meter Shunt -- EBSB20150-25-10-14.4-6.2-V1
Shunt resistance,shunt resistor current measurement,current shunt,current sensing shunt.
Email Details
Material: E-Beam Copper-manganin-Copper
Resistance: 150μΩ±5%
Wire: UL1569 24AWG
Operating temperature range: -40℃ to +80℃
For 80A meter
Shunt is one of the main current sensor used in kWh meter, especially in single phase kWh meter. It's much more economical than current transformer, so three-phase meters is more and more adopting shunt solution with regard to lower cost. Electron Beam Welding shunt (E-B Shunt) is high technology product, and has strict requirement for manganin and copper 99.9% materials, so the quality and appearance is excellent after vacuum welding. -
250 uΩ Meter Shunt -- EBSB15250-27.8-8.3-19.5-3-V1
Shunt resistance,shunt resistor current measurement,current shunt,current sensing shunt.
Email Details
Material: E-Beam Copper-manganin-Copper
Resistance: 250μΩ±5%
Wire: UL1569 24AWG
Operating temperature range: -40℃ to +80℃
For 80A meter
Shunt is one of the main current sensor used in kWh meter, especially in single phase kWh meter. It's much more economical than current transformer, so three-phase meters is more and more adopting shunt solution with regard to lower cost. Electron Beam Welding shunt (E-B Shunt) is high technology product, and has strict requirement for manganin and copper 99.9% materials, so the quality and appearance is excellent after vacuum welding. -
200 uΩ Meter Shunt -- EBSB15200-24.5-9-15.5-V1
Shunt resistance,shunt resistor current measurement,current shunt,current sensing shunt.
Email Details
Material: E-Beam Copper-manganin-Copper
Resistance: 200μΩ±5%
Wire: UL1569 24AWG
Operating temperature range: -40℃ to +80℃
For 80A meter
Shunt is one of the main current sensor used in kWh meter, especially in single phase kWh meter. It's much more economical than current transformer, so three-phase meters is more and more adopting shunt solution with regard to lower cost. Electron Beam Welding shunt (E-B Shunt) is high technology product, and has strict requirement for manganin and copper 99.9% materials, so the quality and appearance is excellent after vacuum welding. -
200μΩ Shunt - EBSG20200-86-8-3.2-V1 ,For meter
Shunt resistance,shunt resistor current measurement,current shunt,current sensing shunt.
Email Details
Material: E-Beam Copper-manganin-Copper
Resistance: 200μΩ±5%
Wire: UL1007 24AWG
Operating temperature range: -40℃ to +80℃
For 80A meter
Shunt is one of the main current sensor used in kWh meter, especially in single phase kWh meter. It's much more economical than current transformer, so three-phase meters is more and more adopting shunt solution with regard to lower cost. Electron Beam Welding shunt (E-B Shunt) is high technology product, and has strict requirement for manganin and copper 99.9% materials, so the quality and appearance is excellent after vacuum welding. -
160μΩ Shunt - EBSG20160-79-9.5-70-4.2-V2 ,For meter
Shunt resistance,shunt resistor current measurement,current shunt,current sensing shunt.
Email Details
Material: E-Beam Copper-manganin-Copper
Resistance: 160μΩ±5%
Wire: UL1007 24AWG
Operating temperature range: -40℃ to +80℃
For 100A meter
Shunt is one of the main current sensor used in kWh meter, especially in single phase kWh meter. It's much more economical than current transformer, so three-phase meters is more and more adopting shunt solution with regard to lower cost. Electron Beam Welding shunt (E-B Shunt) is high technology product, and has strict requirement for manganin and copper 99.9% materials, so the quality and appearance is excellent after vacuum welding. -
Hot
Meter Current Shunt Resistor
Material: Copper-Manganin-Copper
Email Details
Operating Temperature Range: -40℃~+80℃
Shunt is one of the main current sensor used in kWh meter, especially in single phase kWh meter. It's much more economical than current transformer, so three-phase meters is more and more adopting shunt solution with regard to lower cost. Electron Beam Welding shunt (E-B Shunt) is high technology product, and has strict requirement for manganin and copper 99.9% materials, so the quality and appearance is excellent after vacuum welding.