Current Transformer
-
Hot
DCT105W-C3 125A Current Transformer with DC Immunity, CT Metering
125A CT with DC Immunity,For 120A Three phase Wh meter,Easy fixing inside meter, mounted on the bottom case.
Email Details
Strong insulation voltage between the primary and the secondary >4kV/1min
Attractive appearance, casing color is available on request.
Simple assembly, saving production cost.
Easy connection to the primary cables/bus bars of latching relay. -
Hot
DCT107W4 80A Busbar Type Current Transformer with DC Immunity, CT Metering
80A CT with DC Immunity,For Wh meter,Easy fixing inside meter, mounted on the bottom case.
Email Details
Strong insulation voltage between the primary and the secondary >4kV/1min
Attractive appearance, casing color is available on request.
Simple assembly, saving production cost.
Easy connection to the primary cables/bus bars of latching relay. -
Hot
CT006P-A 20A Current Transformer, Monitoring & protection
20A CT,Monitoring & protection,Easy fixing on PCB, saving space for the meters
Email Details
Strong insulation voltage between the primary and the secondary >4kV/1min
Attractive appearance, casing color is available on request
Big inner hole, suitable for any primary cables and bus bars.
Simple assembly, saving production cost -
Hot
CT104P-B1 100A Current Transformer, Monitoring & protection
100A CT,Monitoring & protection,Easy fixing on PCB, saving space for the meters
Email Details
Strong insulation voltage between the primary and the secondary >4kV/1min
Attractive appearance, casing color is available on request
Big inner hole, suitable for any primary cables and bus bars.
Simple assembly, saving production cost -
CTGF-150 Ground Fault Protection CT
Ground fault transformer is a device used to detect, control and protect system ground faults in power distribution system. It can detect the occurrence of ground faults and feed the detection results to the protection equipment in order to trigger the protection action and prevent the system from large failures or losses.
Email Details -
Hot
CT006P-B3 20A Current Transformer, CT Metering
20A CT,For Indirect Wh meter,Monitoring & protection.Easy fixing on PCB, saving space for the meters
Email Details
Strong insulation voltage between the primary and the secondary >4kV/1min
Attractive appearance, casing color is available on request
Big inner hole, suitable for any primary cables and bus bars.
Simple assembly, saving production cost -
Hot
DCT104W 100A Current Transformer with DC Immunity, CT Metering
100A CT with DC Immunity,For 100A Three phase Wh meter,Easy fixing inside meter, mounted on the bottom case.
Email Details
Strong insulation voltage between the primary and the secondary >4kV/1min
Attractive appearance, casing color is available on request.
Simple assembly, saving production cost.
Easy connection to the primary cables/bus bars of latching relay. -
Hot
DCT104P 100A Current Transformer with DC Immunity, CT Metering
100A CT with DC Immunity,For 100A Three phase Wh meter,Easy fixing inside meter, mounted on the bottom case.
Email Details
Strong insulation voltage between the primary and the secondary >4kV/1min
Attractive appearance, casing color is available on request.
Simple assembly, saving production cost.
Easy connection to the primary cables/bus bars of latching relay. -
CT010P-A1 10A Miniature Current Transformer
10A CT,Monitoring & protection,Easy fixing on PCB, saving space for the meters
Email Details
Strong insulation voltage between the primary and the secondary >4kV/1min
Attractive appearance, casing color is available on request
Big inner hole, suitable for any primary cables and bus bars.
Simple assembly, saving production cost