CSPV-ITP-200 High Accuracy Current Transducer, Component-based Fluxgate
- OSWELL
- CHINA
- 10-15天
- 50k
CSPV-ITP-200 is a precise, wide-band and bipolar current transducer based on fluxgate principle. It is mainly for the DC, AC and pulse current measurement fields requiring ultra-high accuracy. The primary and secondary current are isolated from each other and the safety performance is superior.
It is widely used in Medical Device, Special Power Supply, Magnetic Resonance Imaging (MRI) Unit, Smart Power Grid, Test Instrument, New Energy.
Features:
Ultra-high Stability & Accuracy
Primary & Secondary Side Isolation Measurement
Low Temperature Drift
Saturation Detection & Self-recovery Function
Strong Anti-interference Capability
Wide Band & Low Response Time
Electrical Characteristics:
TYPE | CSPV-ITP-200 |
Primary Rated Current IPN(Adc) | ±200 (Nominal) ±240 (Max) |
Primary Overload Current IPM(Adc) | 190A @RM=23Ω 240A @RM=10Ω |
Operating Voltage VC (V) | ±12 (Nominal) ±15 (Max) |
Power Consumption Current IPwr (mA) | ±225 |
Ratio KN | 1:1000 |
Rated Output Current ISN (mA) | ±200 |
Dielectric Strength Vd(PRI-SEC) | 50Hz, 1min, 5kV |
Operating Temperature | -40℃~85℃ |
Storage Temperature | -55℃~95℃ |
Comparative Tracking Index | 275V According to IEC-60112 |
Current Consumption | 15 mA |
Weight | 58±5g |
Dimensions (mm) ±0.8mm
Yellow | Blue | Red | Black |
Iout | -12V | +12V | GND |