Industry News

Saturation of the current transformer

As we mentioned earlier, errors of the CT are mainly caused by the field current Ie. Due to the large excitation impedance in normal operation, Ie is small, so that this error can be ignored. However, when the CT is saturated, the more serious the saturation degree is, the smaller the excitation impedance is and the greatly increased excitation current makes the error of the CT multiply and affects the correct operation of the protection.

Oswell E-Group Ltd. Attend Enlit Europe 2022 today

This exhibition will focus on:Power plant products and equipment systems: power devices, high voltage switches, transmission, distribution network, transformers, current transformers, voltage transformers, power capacitors, high voltage cabinets, monitors, electrical engineering, power supply and accessories, wires and cables, insulation materials, measurement and electronic equipment systems, etc

What is a Smart Meter?

​Smart meter is a metering device that can measure electricity remotely through RS485 data transmission and terminal computer software management. Free automatic power off, timed power off, student apartment malignant load identification and other functions.

Potential Transformer Construction and working

Potential transformer or PT can have the same construction as any normal transformer. It has primary & secondary winding. The number of turns in primary windings is greater than the number of turns in the secondary winding because it is a step-down transformer.

Usage of current transformers

A transformer ​is a device that converts voltage or current proportionally. The function of the transformer is to convert high voltage or high current into standard low voltage (100V) or standard low current (5A or 1A, both referring to the rated value), so as to achieve the standardization and miniaturization of measuring instruments, protection equipment and automatic control equipment.

Three basic types of current transformer

Wound Current Transformer – The transformers primary winding is physically connected in series with the conductor that carries the measured current flowing in the circuit. The magnitude of the secondary current is dependent on the turns ratio of the transformer.

Oswell E-Group Ltd. Will Attend Enlit Europe 2022

Exhibition Scope: Power generation equipment and technology; Transmission and distribution; Power system automation; Metering; Communication and information; Electrical equipment;

How to calculate multiple of ammeter after using shunt

​Motor test measurements often require ammeters to be equipped with multiple shunts to solve the problem of ensuring the required measurement accuracy over a larger measurement range.

Three key parameters of the shunt

The shunt used in the power battery PACK is essentially a resistor to detect the current value flowing. Since the current value is not easy to monitor, most of them are converted into voltage at present, that is, when the current passes, the resistor generates a voltage drop, and the voltage value is detected to calculate the passed current value, which is based on U=IR.

More than 10 Chinese cities allow commercial trials of autonomous cars

More than 10 cities in China have approved commercial trials of autonomous vehicles, inclusive of taxis and urban buses, in designated areas and specific period of time, a senior official announced on Thursday. The application scale of autonomous vehicles is expanding thanks to the rapid development of new technologies such as artificial intelligence, 5G and big data, Han Jinghua, deputy director of the Ministry of Transport's Transportation Services Department, told a news conference.

Get the latest price? We'll respond as soon as possible(within 12 hours)

Privacy policy